RAL 5022 NIGHT BLUE

RAL5022 5022 NIGHT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.41 +/- .05
THEORETICAL COVERAGE 69 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5022 NIGHT BLUE

RAL 5023 DISTANT BLUE

 

RAL5023 5023 DISTANT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

Comments Off on RAL 5023 DISTANT BLUE

RAL 6000 PATINA GREEN

RAL6000 6000 PATINA GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 6000 PATINA GREEN

RAL 6002 LEAF GREEN (TGIC FREE VERSION)

FORMULATION CHANGE **As of Sept  20th 2021, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

 

 

RAL6002A RAL 6002 LEAF GREEN (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.5 TO 3.5 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 ± 0.05
THEORETICAL COVERAGE 130 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 70-80+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

 

 

 

 

 

Comments Off on RAL 6002 LEAF GREEN (TGIC FREE VERSION)

RAL 6003 OLIVE GREEN

ral6003 6003 OLIVE GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.50 +/- .05
THEORETICAL COVERAGE 64 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6003 OLIVE GREEN

RAL 6005 MOSS GREEN

RAL6005 6005 MOSS GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.47 +/- .05
THEORETICAL COVERAGE 66 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6005 MOSS GREEN

RAL 6007 Bottle Green

RAL6007 6007 BOTTLE GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 6007 Bottle Green

BEAD BLAST GUN METAL

BEAD BLAST GUN METAL POLYESTER POWDER

pc1008 BEAD BLAST GUN METAL
CHEMISTRY POLYESTER TGIC C
REGULAR CURE SCHEDULE 375F/15 min
MIN RANGE NA
MAX RANGE NA
RECOMMENDED THICKNESS 1.80 – 3.50 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.70± 0.03
THEORETICAL COVERAGE NA
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) NA
SALT SPRAY 1,000 hours
BALL IMPACT 80 in/lb
SDS Sheet info # #6C – Polyester TGIC (Group C)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS.  USE ZINC RICH PRIMER OVER STEEL PARTS FOR EXTERIOR APPLICATIONS
Comments Off on BEAD BLAST GUN METAL

RAL 6011 RESEDA GREEN

ral6011 6011 RESEDA GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.49 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6011 RESEDA GREEN

RAL 6017 MAY GREEN

ral6017 RAL 6017 MAY GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6017 MAY GREEN

RAL 6033 MINT TURQOISE

ral6033 RAL 6033 MINT TURQUOISE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6033 MINT TURQOISE

RAL 6027A LIGHT GREEN

RAL6027 RAL 6027A LIGHT GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.49 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

 

 

Comments Off on RAL 6027A LIGHT GREEN

RAL 6028 PINE GREEN

ral6028 RAL 6028 PINE GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6028 PINE GREEN

RAL 6029 MINT GREEN

RAL6029 RAL 6029 MINT GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.61 +/- .05
THEORETICAL COVERAGE 60 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

 

Comments Off on RAL 6029 MINT GREEN

RAL 6032 SIGNAL GREEN

RAL6032 RAL 6032 SIGNAL GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 6032 SIGNAL GREEN

RAL 6034

ral6034 RAL 6034 PASTEL TURQUOISE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.49 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6034