RAL 5009 AZURE BLUE

Ral5009 5009 AZURE BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.49 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5009 AZURE BLUE

RAL 5010 GENTIAN BLUE

ral5010 5010 GENTIAN BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 5010 GENTIAN BLUE

RAL 5011 STEEL BLUE

RAL5011 5011 STEEL BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5011 STEEL BLUE

RAL 5012 LIGHT BLUE

RAL5012 5012 LIGHT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5012 LIGHT BLUE

RAL 5013 COBALT BLUE

RAL5013 5013 COBALT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5013 COBALT BLUE

RAL 5014 PIGEON BLUE

RAL5014 5014 PIGEON BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5014 PIGEON BLUE

RAL 5015 SKY BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of July 8th 2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

AXALTA RAL 5015

 

ral5015a 5015 SKY BLUE (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.5 ± 0.05
THEORETICAL COVERAGE 128 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5015 SKY BLUE (TGIC FREE VERSION)

BLACK 20% GLOSS

PC1011 BLACK 20% GLOSS
CHEMISTRY POLYESTER TGIC-FREE
REGULAR CURE TEMP 375F 15-20 MIN
MIN TEMP NA
MAX TEMP 400F 10-15 MIN
RECOMMENDED THICKNESS 2.4-4
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.33 g/cm3
THEORETICAL COVERAGE 144.6 sq.ft/lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 15-25
SALT SPRAY NA
BALL IMPACT 80-120
SDS Sheet info # #4 – Polyester TGIC Free (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on BLACK 20% GLOSS

RAL 5017 TRAFFIC BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of FEB 8th  2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

 

ral5017a 5017 TRAFFIC BLUE  (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 ± 0.05
THEORETICAL COVERAGE 135 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5017 TRAFFIC BLUE (TGIC FREE VERSION)

RAL 5018 TURQOISE BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of Feb 17th 2023, this colour has changed, to the HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

ral5018a

ral5018a (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.5 TO 3.5 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.57 ± 0.05
THEORETICAL COVERAGE 122 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 5018 TURQOISE BLUE (TGIC FREE VERSION)

RAL 5022 NIGHT BLUE

RAL5022 5022 NIGHT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.41 +/- .05
THEORETICAL COVERAGE 69 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5022 NIGHT BLUE

RAL 5023 DISTANT BLUE

 

RAL5023 5023 DISTANT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

Comments Off on RAL 5023 DISTANT BLUE

RAL 6000 PATINA GREEN

RAL6000 6000 PATINA GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.43 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 6000 PATINA GREEN

RAL 6002 LEAF GREEN (TGIC FREE VERSION)

FORMULATION CHANGE **As of Sept  20th 2021, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

 

 

RAL6002A RAL 6002 LEAF GREEN (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.5 TO 3.5 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 ± 0.05
THEORETICAL COVERAGE 130 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 70-80+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

 

 

 

 

 

Comments Off on RAL 6002 LEAF GREEN (TGIC FREE VERSION)

RAL 6003 OLIVE GREEN

ral6003 6003 OLIVE GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.50 +/- .05
THEORETICAL COVERAGE 64 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6003 OLIVE GREEN

RAL 6005 MOSS GREEN

RAL6005 6005 MOSS GREEN
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.47 +/- .05
THEORETICAL COVERAGE 66 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 6005 MOSS GREEN