RAL 4007 PURPLE VIOLET

ral4007 4007 PURPLE VIOLET
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 4007 PURPLE VIOLET

RAL 4008 SIGNAL VIOLET (TGIC FREE VERSION)

FORMULATION CHANGE **As of March 30th  2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

ral4008a 4008 SIGNAL VIOLET (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.51 ± 0.05
THEORETICAL COVERAGE 127 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 4008 SIGNAL VIOLET (TGIC FREE VERSION)

RAL 4010 TELEMAGENTA

RAL4010 4010 TELE MAGENTA
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.5-4 mils
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.41 +/- .05
THEORETICAL COVERAGE 55 sq/ft @ 2.5 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION
Comments Off on RAL 4010 TELEMAGENTA

RAL 5000 VIOLET BLUE

RAL5000 RAL 5000 Violet Blue
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.41 +/- .05
THEORETICAL COVERAGE 69 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5000 VIOLET BLUE

RAL 5004 BLACK BLUE

ral5004 5004 BLACK BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 5004 BLACK BLUE

RAL 5005 SIGNAL BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of Dec 2nd 2021, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

 

ral5005A 5005 SIGNAL BLUE (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.55 ± 0.05
THEORETICAL COVERAGE 124 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 75-85+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5005 SIGNAL BLUE (TGIC FREE VERSION)

RAL 5009 AZURE BLUE

Ral5009 5009 AZURE BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.49 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5009 AZURE BLUE

RAL 5010 GENTIAN BLUE

ral5010 5010 GENTIAN BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 5010 GENTIAN BLUE

RAL 5011 STEEL BLUE

RAL5011 5011 STEEL BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5011 STEEL BLUE

RAL 5012 LIGHT BLUE

RAL5012 5012 LIGHT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5012 LIGHT BLUE

RAL 5013 COBALT BLUE

RAL5013 5013 COBALT BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5013 COBALT BLUE

RAL 5014 PIGEON BLUE

RAL5014 5014 PIGEON BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5014 PIGEON BLUE

RAL 5015 SKY BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of July 8th 2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

AXALTA RAL 5015

 

ral5015a 5015 SKY BLUE (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.5 ± 0.05
THEORETICAL COVERAGE 128 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5015 SKY BLUE (TGIC FREE VERSION)

BLACK 20% GLOSS

PC1011 BLACK 20% GLOSS
CHEMISTRY POLYESTER TGIC-FREE
REGULAR CURE TEMP 375F 15-20 MIN
MIN TEMP NA
MAX TEMP 400F 10-15 MIN
RECOMMENDED THICKNESS 2.4-4
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.33 g/cm3
THEORETICAL COVERAGE 144.6 sq.ft/lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 15-25
SALT SPRAY NA
BALL IMPACT 80-120
SDS Sheet info # #4 – Polyester TGIC Free (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on BLACK 20% GLOSS

RAL 5017 TRAFFIC BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of FEB 8th  2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

 

ral5017a 5017 TRAFFIC BLUE  (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 ± 0.05
THEORETICAL COVERAGE 135 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

Comments Off on RAL 5017 TRAFFIC BLUE (TGIC FREE VERSION)

RAL 5018 TURQOISE BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of Feb 17th 2023, this colour has changed, to the HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

ral5018a

ral5018a (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.5 TO 3.5 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.57 ± 0.05
THEORETICAL COVERAGE 122 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 5018 TURQOISE BLUE (TGIC FREE VERSION)