RAL 3000 FLAME RED (TGIC FREE VERSION)

FORMULATION CHANGE **As of June 10th 2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

AXALTA RAL 3000

 

 

 

ral3000a 3000 FLAME RED (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 400F/10 MIN
MIN TEMP 0
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 ± 0.05
THEORETICAL COVERAGE 130 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 70-80+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

 

Comments Off on RAL 3000 FLAME RED (TGIC FREE VERSION)

RAL 3001 SIGNAL RED

RAL3001 3001 SIGNAL RED
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.5 TO 3.5 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.46 +/- .05
THEORETICAL COVERAGE 53 sq/ft @ 2.5 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

Comments Off on RAL 3001 SIGNAL RED

RAL 3002 CARMINE RED

ral3002 3002 CARMINE RED
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.5 TO 3.5 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.46 +/- .05
THEORETICAL COVERAGE 53 sq/ft @ 2.5 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 3002 CARMINE RED

RAL 3003 RUBY RED (TGIC FREE VERSION)

FORMULATION CHANGE **As of June 8th 2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

AXALTA RAL 3003

 

 

ral3003a RAL 3003 RUBY RED (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.45 ± 0.05
THEORETICAL COVERAGE 133 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 75-85
SALT SPRAY 1,000 hours
BALL IMPACT 140 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 3003 RUBY RED (TGIC FREE VERSION)

RAL 3005 WINE RED

RAL3005 3005 WINE RED
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

 

 

 

 

 

 

 

 

 

Comments Off on RAL 3005 WINE RED

RAL 3015 LIGHT PINK (TGIC FREE VERSION)

FORMULATION CHANGE **As of Aug 8th 2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

AXALTA RAL 3015

 

 

ral3015a RAL 3015  (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.45 ± 0.05
THEORETICAL COVERAGE 133 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 75-85
SALT SPRAY 1,000 hours
BALL IMPACT 140 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 3015 LIGHT PINK (TGIC FREE VERSION)

RAL 3018A STRAWBERRY RED (TGIC FREE VERSION)

FORMULATION CHANGE **As of June 16th 2023, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

ral3018a ral3018a
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.62 ± 0.05
THEORETICAL COVERAGE 119 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 70-80+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 3018A STRAWBERRY RED (TGIC FREE VERSION)

RAL 3020 TRAFFIC RED (TGIC FREE VERSION)

FORMULATION CHANGE **As of Aug 8th 2021, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

AXALTA RAL 3020 TRAFFIC RED

 

 

 

ral3020a 3020 TRAFFIC RED (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.52 ± 0.05
THEORETICAL COVERAGE 127 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 75-85+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS-CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.
Comments Off on RAL 3020 TRAFFIC RED (TGIC FREE VERSION)

RAL 4003 HEATHER VIOLET

ral4003 4003 HEATHER VIOLET
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.47 +/- .05
THEORETICAL COVERAGE 66 sq/ft @ 2 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/

 

 

 

 

 

 

Comments Off on RAL 4003 HEATHER VIOLET

RAL 4005 BLUE LILAC

ral4005 4005 BLUE LILAC
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.48 +/- .05
THEORETICAL COVERAGE 65 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION

 

 

Comments Off on RAL 4005 BLUE LILAC

RAL 4007 PURPLE VIOLET

ral4007 4007 PURPLE VIOLET
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY n/a
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 4007 PURPLE VIOLET

RAL 4008 SIGNAL VIOLET (TGIC FREE VERSION)

FORMULATION CHANGE **As of March 30th  2022, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

ral4008a 4008 SIGNAL VIOLET (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.51 ± 0.05
THEORETICAL COVERAGE 127 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-90+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 4008 SIGNAL VIOLET (TGIC FREE VERSION)

RAL 4010 TELEMAGENTA

RAL4010 4010 TELE MAGENTA
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.5-4 mils
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.41 +/- .05
THEORETICAL COVERAGE 55 sq/ft @ 2.5 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION
Comments Off on RAL 4010 TELEMAGENTA

RAL 5000 VIOLET BLUE

RAL5000 RAL 5000 Violet Blue
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE SCHEDULE 375F/10 MIN
MIN RANGE 350F/15 MIN
MAX RANGE 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.41 +/- .05
THEORETICAL COVERAGE 69 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, CLEAR COAT IS NOT NEEDED BUT WILL ADD EXTRA PROTECTION.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5000 VIOLET BLUE

RAL 5004 BLACK BLUE

ral5004 5004 BLACK BLUE
CHEMISTRY SD POLYESTER TGIC
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP 400F/7 MIN
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.42 +/- .05
THEORETICAL COVERAGE 68 sq/ft @ 2.0 mils
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 80-95+
SALT SPRAY 1,000 hours
BALL IMPACT 120 in/lb
SDS Sheet info # #6B – Polyester TGIC (Group B)
SDS link https://emeraldcoatings.com/sds-sheets/
Comments Off on RAL 5004 BLACK BLUE

RAL 5005 SIGNAL BLUE (TGIC FREE VERSION)

FORMULATION CHANGE **As of Dec 2nd 2021, this colour has changed, to the Axalta HHA TGIC Free formulation.  Do not mix this powder with previous batches.

 

 

ral5005A 5005 SIGNAL BLUE (NEW TGIC FREE VERSION, do not mix with old version)
CHEMISTRY HAA POLYESTER TGIC FREE
REGULAR CURE TEMP 375F/10 MIN
MIN TEMP 350F/15 MIN
MAX TEMP NA
RECOMMENDED THICKNESS 2.0 TO 3.0 MILS
PENCIL HARDNESS 2H
SPECIFIC GRAVITY 1.55 ± 0.05
THEORETICAL COVERAGE 124 ft /lb/mil
PENCIL HARDNESS 2H minimum
GLOSS LEVEL (60°) 75-85+
SALT SPRAY 1,000 hours
BALL IMPACT 160 in/lbs
SDS Sheet info # #15 HAA POLYESTER TGIC FREE
SDS link https://emeraldcoatings.com/sds-sheets/
HAA, TGIC FREE, RAL COLOUR, DO NOT MIX WITH PREVIOUS TGIC VERSION, ENSURE GOOD GUN CLEANING BETWEEN COLOUR CHANGES TO PREVENT CROSS CONTAMINATION.  WEATHER RESISTANT POWDER COATING FOR INTERIOR AND EXTERIOR APPLICATIONS, clear coat is not needed but will add extra protection.   When coating in 2-3 stages, always particularly cure the base coat around 50-75% of the recommended cure schedule to allow the top coat to properly cross-link with the base coat. This method of curing will result in the best possible bond between coats. over curing the base coat can cause possible Delamination between coatings.

 

Comments Off on RAL 5005 SIGNAL BLUE (TGIC FREE VERSION)